Feature properties¶
Feature property |
Description |
|---|---|
Enable a feature |
|
Identify a sub version (template_id) |
|
Set the device RF Tx power (in dBm) |
|
Set the device RF modes |
|
Device power type |
|
configure the serial interface for ate and co-processor |
|
Disable BLE LGS protocol |
|
Device overheat alert detection |
|
Device overheat alert threshold |
|
Feature option |
|
Feature IO instance |
|
Detect and save the switches type |
|
Switch action type |
|
Bluetooth MESH compatibility mode |
|
Activation de la détection de charge nulle |
|
Bluetooth MESH compatibility mode |
|
Variation mode |
|
Current level of the dimmable switch |
|
Min level of the dimmable controller |
|
Max level of the dimmable controller |
|
level controller edge control type |
|
level max possible when dimmer is calibrate |
|
Shutter switch direction (up/down) |
|
Time Run On (in msecond) |
|
Shutter controller auto recalibration |
|
Shutter controller calibration up |
|
Shutter controller calibration down |
|
Shutter controller calibration rotation acw |
|
Shutter controller calibration rotation cw |
|
Shutter controller rotation step |
|
Shutter controller report timeout (1s step) |
|
Shutter controller pulse time in ms |
|
Shutter controller internal power supply |
|
ventilation controller boost temporisation (min) |
|
ventilation |
|
ventilation |
|
ventilation |
|
Motion detector luminosity level |
|
Smart meter driver operating mode |
|
Contract subscribed apparent power |
|
Tariff contract name as declared by the meter or DSO |
|
Raw tariff period code as received from the meter |
|
Raw meter status register |
|
Meter supply wiring mode |
|
Period for publishing periodic instantaneous measurements |
|
to terminate the LPN friendship |
|
Smoke detector test |
|
onoff-current-state |
|
level-current-state |
|
shutter-current-state |
|
ventilation-current-state |
|
pilot-wire-current-state |
|
sat-hue-current-state |
|
Thermostat mode |
|
Temperature-setpoint |
|
Thermostat derogation duration |
|
Tolérance (température d’hysteresis) |
|
Temperature Hors gel |
|
Choix du Capteur de température |
|
Boutons + / - activé |
|
Consigne manuelle maximale |
|
Running-program id |
|
Fonction Maison Vigilante - liste des détections |
|
Fonction Maison Dissuasive - liste des actions |
|
Fonction Maison Vigilante - Periode de grâce |
|
Wifi settings scan operations |
|
Wifi settings connect operations |
|
Wifi settings ssid |
|
Wifi settings password |
|
The realm Id where the gateway is |
|
a register transmited over the shell |
|
Co-processor FW version |
|
Detect and save tram infrared |
feature-enable¶
Enable a feature
Ce paramètre sert à indiquer qu’une fonctionnalité est active.
Label:feature-enable
Id: 0x0000
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Feature disabled |
1 |
Feature enabled |
custom-id¶
Identify a sub version (template_id)
Label:custom-id
Id: 0x0001
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_MODE_NO_HARD_INIT
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
Default template |
device-rf-tx-power¶
Set the device RF Tx power (in dBm)
Label:device-rf-tx-power
Id: 0x0002
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
0DBM |
2 |
POS2DBM |
3 |
POS3DBM |
4 |
POS4DBM |
5 |
POS5DBM |
6 |
POS6DBM |
7 |
POS7DBM |
8 |
POS8DBM |
device-rf-modes¶
Set the device RF modes
Label:device-rf-modes
Id: 0x0003
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
BLE 1Mbits |
1 |
BLE 2Mbits |
2 |
NRF_62K5BIT Long Range |
3 |
RADIO_END |
4 |
SIG BLE Long Range |
device-power-type¶
Device power type
Label:device-power-type
Id: 0x000A
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Energy harvesting powered |
1 |
Battery powered |
2 |
230V powered |
device-serial-mode¶
configure the serial interface for ate and co-processor
Label:device-serial-mode
Id: 0x0010
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
serial for ate enabled |
1 |
serial for co-processor |
2 |
serial disabled |
ble-lgs-disable¶
Disable BLE LGS protocol
Label:ble-lgs-disable
Id: 0x0011
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Enable LGS |
1 |
Disable LGS |
overheat-alert¶
Device overheat alert detection
Cette FP stocke l’état de l’alerte d’échauffement en cours : disabled = pas d’alerte, activated = alerte en cours
Label:overheat-alert
Id: 0x0020
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Disabled |
1 |
Activated |
overheat-alert-threshold¶
Device overheat alert threshold
Label:overheat-alert-threshold
Id: 0x0021
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: centidegree
Values (int) |
Description |
|---|---|
5000 |
default |
5000 |
default |
6000 |
default |
7000 |
default |
8500 |
default |
feature-option¶
Feature option
Label:feature-option
Id: 0x00FD
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
feature-io¶
Feature IO instance
Label:feature-io
Id: 0x00FE
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
1 |
in-out-1 |
2 |
in-out-2 |
3 |
in-out-3 |
switches-detection¶
Detect and save the switches type
Label:switches-detection
Id: 0x00FF
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
no detection |
switch-type¶
Switch action type
Label:switch-type
Id: 0x0100
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
Undefined |
1 |
Single Push NO |
2 |
Single Push NC |
3 |
Two ways |
onoff-switch-type-compatibility-mode¶
Bluetooth MESH compatibility mode
Label:onoff-switch-type-compatibility-mode
Id: 0x0101
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
BLE MESH Proprietary mode (toggle) |
1 |
BLE MESH SIG Mode (onoff) |
output-zero-load-control¶
Activation de la détection de charge nulle
Si la FP est enabled, la feature mesure la consommation instantanée C toutes les 10s et déclenche l’alerte de charge nulle si C<2W.
Label:output-zero-load-control
Id: 0x0103
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Disable |
1 |
Enable |
level-switch-compatibility-mode¶
Bluetooth MESH compatibility mode
Label:level-switch-compatibility-mode
Id: 0x0111
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
BLE MESH Proprietary mode |
1 |
BLE MESH SIG Mode |
level-switch-variation-mode¶
Variation mode
Label:level-switch-variation-mode
Id: 0x0112
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
Default mode |
1 |
No double push option |
2 |
Night light mode |
level-switch-current-level¶
Current level of the dimmable switch
Label:level-switch-current-level
Id: 0x0113
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
min level |
100 |
max level |
level-controller-level-min¶
Min level of the dimmable controller
Label:level-controller-level-min
Id: 0x0114
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
level min |
25 |
default level min |
level-controller-level-max¶
Max level of the dimmable controller
Label:level-controller-level-max
Id: 0x0115
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
100 |
level max |
75 |
default level max |
level-controller-edge-control¶
level controller edge control type
Label:level-controller-edge-control
Id: 0x0116
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
leading edge control |
1 |
trailing edge control |
level-controller-max-level-calibrate¶
level max possible when dimmer is calibrate
Label:level-controller-max-level-calibrate
Id: 0x0117
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
not calibrate |
shutter-switch-direction¶
Shutter switch direction (up/down)
Label:shutter-switch-direction
Id: 0x0152
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
up |
1 |
down |
controller-time-run-on¶
Time Run On (in msecond)
Label:controller-time-run-on
Id: 0x8100
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
timer-disabled |
shutter-controller-auto-recalibration¶
Shutter controller auto recalibration
Label:shutter-controller-auto-recalibration
Id: 0x8150
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
Auto recalibration disabled |
1 |
Auto recalibration enabled |
shutter-controller-calibration-up¶
Shutter controller calibration up
Label:shutter-controller-calibration-up
Id: 0x8151
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
Calibration min |
65535 |
Calibration max |
shutter-controller-calibration-down¶
Shutter controller calibration down
Label:shutter-controller-calibration-down
Id: 0x8152
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
Calibration min |
65535 |
Calibration max |
shutter-controller-calibration-rotation-acw¶
Shutter controller calibration rotation acw
Label:shutter-controller-calibration-rotation-acw
Id: 0x8155
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
Calibration min |
65535 |
Calibration max |
shutter-controller-calibration-rotation-cw¶
Shutter controller calibration rotation cw
Label:shutter-controller-calibration-rotation-cw
Id: 0x8156
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
Calibration min |
65535 |
Calibration max |
shutter-controller-rotation-step¶
Shutter controller rotation step
Label:shutter-controller-rotation-step
Id: 0x8157
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
rotation step min |
10 |
rotation step min |
90 |
rotation step max |
shutter-controller-report-timeout¶
Shutter controller report timeout (1s step)
Label:shutter-controller-report-timeout
Id: 0x8158
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
Timeout min |
72000 |
Timeout max |
shutter-controller-pulse-ms¶
Shutter controller pulse time in ms
Label:shutter-controller-pulse-ms
Id: 0x8159
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
50 |
pulse min |
4000 |
pulse max |
300 |
Default pulse |
shutter-controller-internal-power-supply¶
Shutter controller internal power supply
Label:shutter-controller-internal-power-supply
Id: 0x8160
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
No internal power supply available |
1 |
Internal power supply available |
ventilation-controller-boost-tempo¶
ventilation controller boost temporisation (min)
Label:ventilation-controller-boost-tempo
Id: 0x0162
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
Timeout min |
30 |
Default Timeout |
255 |
Timeout max |
ventilation-level-off¶
ventilation
Label:ventilation-level-off
Id: 0x0170
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
104 |
default |
ventilation-level-normal¶
ventilation
Label:ventilation-level-normal
Id: 0x0171
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
207 |
default |
ventilation-level-forced¶
ventilation
Label:ventilation-level-forced
Id: 0x0172
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
motion-detector-luminosity¶
Motion detector luminosity level
Label:motion-detector-luminosity
Id: 0x0202
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
smart-meter-driver-mode¶
Smart meter driver operating mode
- EN:
Indicates which low-level metering driver mode is used (e.g. legacy / standard teleinfo for Linky, or another country-specific mode). This parameter is mostly intended for debugging and advanced support.
- FR:
Indique quel mode de driver bas-niveau est utilisé pour le compteur (par exemple téléinfo historique / standard pour Linky, ou tout autre mode spécifique à un pays). Ce paramètre est principalement destiné au debug et au support avancé.
Label:smart-meter-driver-mode
Id: 0x0220
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Mode téléinfo historique |
1 |
Mode téléinfo standard |
2 |
Autre mode de driver compteur intelligent |
smart-meter-contract-subscribed-power¶
Contract subscribed apparent power
Puissance apparente souscrite au contrat d’alimentation électrique. Pour les compteurs Linky français, cette valeur est dérivée d’ISOUSC (TIC historique) ou directement lue dans PREF (TIC standard) et est exprimée en kVA.
Label:smart-meter-contract-subscribed-power
Id: 0x0221
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
smart-meter-tariff-contract-name¶
Tariff contract name as declared by the meter or DSO
Nom ou code brut de l’offre tarifaire, tel qu’exposé par le compteur. Pour les compteurs Linky français, cette information provient de OPTARIF (TIC historique) ou NGTF (TIC standard). Cette valeur est spécifique au pays et au fournisseur (HP/HC, Tempo, etc.).
Label:smart-meter-tariff-contract-name
Id: 0x0222
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (string) |
Description |
|---|---|
0 |
default |
smart-meter-tariff-period-raw-code¶
Raw tariff period code as received from the meter
Code brut représentant la période tarifaire en cours, directement mappé depuis le protocole du compteur. Pour les compteurs Linky français, il s’agit de PTEC (TIC historique) ou LTARF (TIC standard). Les abstractions tarifaires de plus haut niveau sont construites à partir de cette information.
Label:smart-meter-tariff-period-raw-code
Id: 0x0223
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (string) |
Description |
|---|---|
0 |
default |
smart-meter-status-register¶
Raw meter status register
Registre de statut brut lu directement sur le compteur. Cette valeur est interprétée par le driver spécifique au pays pour en déduire des indicateurs de statut de plus haut niveau (par exemple commande tarifaire, surcharge, mode production).
Label:smart-meter-status-register
Id: 0x0224
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
smart-meter-supply-wiring-mode¶
Meter supply wiring mode
Indique si le compteur et l’installation électrique sont configurés en monophasé ou en triphasé.
Label:smart-meter-supply-wiring-mode
Id: 0x0225
Access Mode: FP_ACCESS_MESH_R|FP_ACCESS_MESH_RAM_ONLY
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
Alimentation monophasée |
1 |
Alimentation triphasée |
smart-meter-publish-period¶
Period for publishing periodic instantaneous measurements
Définit la période, en millisecondes, utilisée pour publier les mesures instantanées du compteur sur le réseau Mesh de manière périodique.
Label:smart-meter-publish-period
Id: 0x0226
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
10000 |
default |
terminate-friendship-lpn¶
to terminate the LPN friendship
Label:terminate-friendship-lpn
Id: 0x0300
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (enum) |
Description |
|---|---|
0 |
terminate friendship |
smoke-detector-test¶
Smoke detector test
Label:smoke-detector-test
Id: 0x0400
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: True
Unité:
Values (enum) |
Description |
|---|---|
0 |
test inactive on Smoke detector (no Alarm) |
1 |
test active on Smoke detector (Alarm) |
onoff-current-state¶
onoff-current-state
Label:onoff-current-state
Id: 0xA000
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
level-current-state¶
level-current-state
Label:level-current-state
Id: 0xA001
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
65536 |
default |
shutter-current-state¶
shutter-current-state
Label:shutter-current-state
Id: 0xA002
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
ventilation-current-state¶
ventilation-current-state
Label:ventilation-current-state
Id: 0xA003
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
1 |
default |
pilot-wire-current-state¶
pilot-wire-current-state
Label:pilot-wire-current-state
Id: 0xA004
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
sat-hue-current-state¶
sat-hue-current-state
Label:sat-hue-current-state
Id: 0xA005
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
thermostat-mode¶
Thermostat mode
Label:thermostat-mode
Id: 0xA020
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
temperature-setpoint¶
Temperature-setpoint
Label:temperature-setpoint
Id: 0xA021
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (int) |
Description |
|---|---|
2000 |
default |
derogation-duration¶
Thermostat derogation duration
Label:derogation-duration
Id: 0xA022
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: minute
Values (int) |
Description |
|---|---|
0 |
Timeout min |
180 |
Default Timeout |
1440 |
Timeout max |
thermostat-hysteresis-temp¶
Tolérance (température d’hysteresis)
C’est la différence acceptable entre la température de consigne et la température relevée au delà de laquelle il est nécessaire de déclencher la chauffe Min 0,1°C, max 2,0°C. Valeur par défaut 0,5°C
Label:thermostat-hysteresis-temp
Id: 0xA023
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: decidegree
Values (int) |
Description |
|---|---|
50 |
min |
50 |
default |
200 |
max |
thermostat-no-frost-temp¶
Temperature Hors gel
C’est la température cible lorsque le mode de fonctionnement hors gel est activé. Ce paramètre n’est défini que pour les thermostats à consigne en température. 7° par défaut.
Label:thermostat-no-frost-temp
Id: 0xA024
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: decidegree
Values (int) |
Description |
|---|---|
500 |
min |
700 |
default |
1500 |
max |
thermostat-sensor-address¶
Choix du Capteur de température
Par défaut « lui-même» . On stockera ds une FP l’adresse source du capteur à écouter (le thermostat souscrira à C000 et verra “passer” tous les capteurs)
Label:thermostat-sensor-address
Id: 0xA025
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: address
Values (int) |
Description |
|---|---|
0 |
default |
thermostat-manual-setting-temp¶
Consigne manuelle maximale
Ce paramètre définit la température de consigne maximum pour le mode de fonctionnement manuel ou pour une dérogation. Ce paramètre n’est défini que pour les thermostats à consigne en température.
Label:thermostat-manual-setting-temp
Id: 0xA027
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: decidegree
Values (int) |
Description |
|---|---|
750 |
min |
2500 |
default |
3000 |
max |
thermostat-running-program¶
Running-program id
Thermostat : prog_id du programme en cours (0 si pas de prog)
Label:thermostat-running-program
Id: 0xA028
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité: id
Values (int) |
Description |
|---|---|
0 |
default |
burglar-detection-events¶
Fonction Maison Vigilante - liste des détections
Bit 0: Me notifier en cas de detection de mouvement (true par défaut)
Bit 1: Me notifier en cas de changement de statut sur un produit (true par défaut)
Label:burglar-detection-events
Id: 0xA030
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: bitfields
Values (int) |
Description |
|---|---|
0 |
min |
3 |
Default |
3 |
max |
burglar-action-events¶
Fonction Maison Dissuasive - liste des actions
Bit 0: Faire sonner les détecteurs de fumée (off par défaut)
Bit 1: Fermer les volets (off par défaut)
Bit 2: Allumer les lumières (off par défaut)
Label:burglar-action-events
Id: 0xA031
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: bitfields
Values (int) |
Description |
|---|---|
0 |
min |
0 |
Default |
7 |
max |
burglar-grace-period¶
Fonction Maison Vigilante - Periode de grâce
La période de grâce permet à l’utilisateur :
d’avoir un délai au départ du logement : à l’activation de la maison vigilante la période de grâce permet de sortir du logement en passant devant un capteur ou en éteignant une lumière sans déclencher une alerte. L’activation est effective au delà de la période de grâce.
d’avoir un délai à l’arrivée dans le logement : à la détection (je passe devant le capteur de mouvement par exemple) j’ai la durée de la période de grâce pour désactiver la maison vigilante avant le déclenchement de l’alerte (envoi d’une notification).
Label:burglar-grace-period
Id: 0xA032
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité: second
Values (int) |
Description |
|---|---|
1 |
min |
30 |
Default |
120 |
max |
wifi-scan¶
Wifi settings scan operations
Label:wifi-scan
Id: 0xB000
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
wifi-connect¶
Wifi settings connect operations
Label:wifi-connect
Id: 0xB001
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
wifi-ssid¶
Wifi settings ssid
Label:wifi-ssid
Id: 0xB002
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
wifi-password¶
Wifi settings password
Label:wifi-password
Id: 0xB003
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
realm-uuid¶
The realm Id where the gateway is
Label:realm-uuid
Id: 0xB010
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
shell-register¶
a register transmited over the shell
Label:shell-register
Id: 0xB011
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W (internal)
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
co-processor-fw-version¶
Co-processor FW version
Label:co-processor-fw-version
Id: 0xF000
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W
Adjustable: False
Unité:
Values (array) |
Description |
|---|---|
0 |
default |
infrared-detection¶
Detect and save tram infrared
Label:infrared-detection
Id: 0x0500
Access Mode: FP_ACCESS_SERIAL_R|FP_ACCESS_SERIAL_W|FP_ACCESS_MESH_R|FP_ACCESS_MESH_W|FP_MODE_NO_HARD_INIT (internal)
Adjustable: True
Unité:
Values (int) |
Description |
|---|---|
0 |
default |
Revision date : 28 mai 2026