Electrical flexibility management

Les produits de gestion d’énergie de la solution disposent de la fonction de flexibilité électrique.

Off-peak control

A load under off-peak control switches on when off-peak hours start and stops when peak hours start. The information comes from a product fitted with the Smart meter function, which publishes the meter’s off-peak / peak state.

Control is set load by load, through the smart-meter-control feature property.

📋 Requirement: In factory configuration, off-peak control is disabled.

📋 Requirement: With control enabled, an On/Off output goes On when off-peak hours start and Off when peak hours start.

📋 Requirement: With control enabled, a heating device goes to Comfort mode when off-peak hours start and to Stop mode when peak hours start.

📋 Requirement: Another command — Mobile App, scenario, motion detector — sets the load state until the next switch to off-peak or peak hours.

📋 Requirement: Off-peak control works locally, on the household mesh network alone.